SMC VIDEO LIBRARY
Air Management System
pressure control and measurement of compressed air
・Space-saving
・Easy installation and replacement
・Easy replacement of filter elements
Directional Control Valves
Air Cylinders
・Actuator stroke position is output with an analog signal.
・Repeatability: 0.1 mm
・IO-Link compatible
Air Grippers
・Plug & play configuration for immediate use URCap compatible, Easy programming ・Compact, lightweight product with high gripping force due to air operation Operate by simply connecting 1 air supply tube and an electrical wiring M8 connector. ・Integrated solenoid valve and speed adjustment mechanism ・Standards: ISO9409-1-50-4-M6
DetailsElectric Actuators
・A Wide Variety for Different Applications Transfer, Lift Up/Push, Rotate, Grip
Details・Circular arc grooves allow for high rigidity and high precision. ・Moment resistance: Improved by up to 61% ・Table displacement: Reduced by up to 50% ・With internal battery-less absolute encoder Restart from the last stop position is possible after recovery of the power supply. Reduced maintenance (No need for control or replacement) ・Positioning repeatability: ±0.01 mm
Details・Built-in Intermediate Supports ・A maximum speed of 1,800 mm/s1 has been achieved throughout the entire stroke! ・The use of intermediate supports results in reduced deflection of the ball screw when a long stroke is used. ・Max. stroke: 1,790 mm ・Horizontal work load: 85 kg (For the 10 mm lead)
DetailsVacuum Equipment
・Compact3 types available: 100, 300, and 600 L/min (ANR) ・Air consumption 90% reduction (For the ZL3, ZL6) ・Weight Max. 60% reduction ZL112 (Existing model): 450 g / ZL1: 180 g ・3-stage diffuser construction (For the ZL1) Suction flow rate increased by 250%
Details・Adsorption transfer of workpiece with a soft film flexible packaging ・Thin film skirt and special shape rib ・Guide attachment function ・Acceleration/deceleration: Adsorption transfer possible at 4G ・FDA (USA Food and Drug Administration) regulations compliant materials are used for pad and guide attachment. ・Blue colored pad Easy to distinguish the vacuum pad by color during contamination inspection
Details・For the adsorption transfer of thin cloths, films, printed circuit boards, etc. ・Energy saving: Max. 72% reduction (Comparison of air consumption to lifting force) ・High lifting force: 28.3 N 5.7 times that of the existing model (Existing model: 5.0 N → ZNC60: 28.3 N) ・3 types of body materials: Aluminum, Resin, Stainless steel ・Attachment With stopper: Prevents workpiece slippage With vibration suppression cover: Suppresses the vibration noise of thin workpieces
Details・Plug & play configuration for immediate use URCaps compatible Easy programming ・Operate by simply connecting 1 compressed air supply tube and an electrical wiring M8 connector. ・Integrated vacuum ejector, air supply/release valve, pressure sensor,and cups ・Standards: ISO9409-1-50-4-M6
DetailsModular F.R.L./Booster Regulators
・Flat design modular Products for purification, pressure control and measurement of compressed air ・Space-saving ・Easy installation and replacement ・Easy replacement of filter elements
Details・Air consumption: Max. 40% reduction (Based on SMC’s measuring conditions) Operates by recycling air through the exhaust return circuit ・Operation noise: 65 dB (A) 15 dB (A) reduction compared with the existing model (VBA series) (Based on SMC’s measuring conditions) ・Charging time: Max. 50% shorter ・Operating cycles: 50 million cycles or more Maintenance frequency is reduced due to improved life. (Based on SMC’s test conditions) ・Compatible with vertical and horizontal installation ・Mounting compatibility with the existing model (VBA series)
DetailsSpeed Controllers
・2-speed control reduces cycle time Allows for the impact relaxation of the stroke end Allows for the 2-speed control of cylinders The deceleration position (cushion timing) and 2nd speed (cushion intensity) can be adjusted. ・Possible to control flow rate values using an adjustment handle with graduations ・Space saving Maximum 76% reduction of occupying space (196 cm3 ← 811 cm3)
DetailsDifference between speed controller control and deceleration controller control
DetailsAir Preparation Equipment
・Applicable for the high-temperature environments Ambient temperature : Max. 45℃ Inlet air temperature : Max. 65℃
Details・Applicable for the high-temperature environments of tropical regions Ambient temperature : Max. 45℃ Inlet air temperature : Max. 65℃ Dew point range : 3℃ to 20℃ ・Power supply voltage : Single-phase 230 VAC (50 Hz)
Details・Applicable for the high-temperature environments
Ambient temperature : Max. 45℃
Inlet air temperature : Max. 65℃
・Power supply voltage : Single-phase 230 VAC (50 Hz)
・Applicable for the high-temperature environments Ambient temperature : Max. 113°F (45°C) Inlet air temperature : Max. 149°F (65°C) ・Power supply voltage: Single-phase 230 VAC (60 Hz)
Details・Improved foreign matter resistance ・Increase in condensate discharge Drain discharge: Max. 100 cm3/cycle (3 times that of the current model) ・Improved environmental resistance: Transparent bowl guard can protect the inner bowl
Details・Flat design modular Products for purification,
pressure control and measurement of compressed air
・Space-saving
・Easy installation and replacement
・Easy replacement of filter elements
Blow Guns
・Increased impact force due to higher peak pressure Drastic reduction in air consumption and labor time ・Application Examples: Can quickly remove foreign matter, etc. that is hard to remove with existing blow devices
DetailsSwitches/Sensors
・Visualization of Settings ・Simple 3-Step Setting ・Easy Screen Switching Setting is possible while checking the measured value.
Details・It is possible to change the settings while checking the measured value.
・IO-Link
・Angled display
Good visibility from various mounting positions
・Applicable fluid Air, N2
・Flow range: Max. 12000 L/min
・Flow ratio 100:1
Wide range of flow measurement with one product
・Flat design modular Products for purification,
pressure control and measurement of compressed air
・Space-saving
・Easy installation and replacement
・Easy replacement of filter elements
Static Neutralization Equipment
・Potential amplitude of 25 V or less with the dual AC type (At an installation height of 300 mm) ・Rapid neutralization of static electricity by a feedback sensor ・Reduction of adjustment and maintenance labor by an auto balance sensor
Details・The controller and high-voltage power supply module can be
mounted separately.
・Space saving: Height 37 mm x Width 30 mm (Bar type)
Thickness 16 mm x Width 53 mm x Height 32 mm
(Nozzle type)
・One controller can control a maximum of 4 ionizers.
・Potential amplitude: 25 V or less
・Rapid neutralization of static electricity: Max. speed of 0.1 s
・3 types of emitter cartridges
High speed static neutralization cartridges
Energy saving static neutralization cartridge
Energy saving high-efficiency cartridge
・Static neutralization is possible even when air is not being
supplied.
・Lightweight: Only 200 g (Body weight)
・Reduced operating force, Easy to hold grip
・Lighting LED
・Blow setting function
Select from continuous blow or pulse blow.
・Rapid static neutralization: 0.3 s
(Distance: 150 mm,Operating pressure: 0.2 MPa)
・Thinnest: 40 mm thick
・Fastest: Rapid static neutralization 0.5 seconds
・Offset voltage (Ion balance): ±5 V
・Stable static neutralization performance, Easier maintenance
Series
Process Valves
・Improved environmental resistance due to the stainless steel
coil cover [IP67 enclosure]
・Body material: Stainless steel, Brass/Bronze, Aluminum
・Environmental resistance: IP67 enclosure
(IP65 for models with a DIN terminal)
・Energy saving
Coil force: 10% increase (Compared with the existing model),
Power consumption: 14% reduction
(Compared with the existing model)
・360o lead wire insertion and removal is possible.
・Life: 10 million cycles or more/10 times or more
・High peak pressure and low air consumption
Peak pressure: 15% increase
Air consumption: 35% reduction
Temperature Control Equipment
・The temperatures of 2 fluid channel systems can be controlled individually by 1 chiller. ・Space saving, Reduced wiring Footprint reduced by 21% One power supply system for 2 channels ・Energy saving Power consumption reduced by 17%
Details・Operable without the need to remove the unit from the rack
・Front Access: Simple to control, service and maintain with all filters
and drainage via the front panel
・Space Saving: Multiple chillers can be mounted to a 19-inch rack.
・Compact: 130 mm (Width) x 210 mm (Height) x 150 mm (Depth) ・Low-noise design (at low load): 37 dB ・Cooling capacity: 220 W ・Temperature stability: ±0.1°C ・Set temperature range: 10°C to 60°C ・Superior temperature control Now only takes about 41 seconds to lower the temperature by 10°C 86% reduction (41 s ← 294 s) ∗ Compared with the existing product HECR002 ∗ Time to change the circulating fluid temperature from 30°C to 20°C (when the circulating fluid IN and OUT are directly connected)
DetailsP.G.Information
・Push button type compact blow gun
・Compact plug type with an integrated BC element!
Applications
・Weight reduced by up to 24% with a shorter guide rod and thinner plate. ・The space required between the bottom of the cylinder body and your equipment is reduced because of the shortening of the guide rod by a max. of 22 mm.
Details・The allowable moment of inertia is 3 times higher.
(The same as the heavy-duty MK2 series)
・It is possible to mount small auto switches on 4 surfaces.
・3-point-stopping is possible.
・Suitable for applications such as distributing workpieces to the left, right, and center.
・Can be operated with one valve
・Ejector and pad are integrated. Space saving with reduced piping labor! ・2-stage ejector Suction flow rate increased by 50%, Air consumption reduced by 30%
Details・By supplying compressed air, large blow and vacuum flow rates are available.
・Large passage diameter available for the suction of machining chips, particles, etc.
・Maintenance-free
・Potential amplitude of 25 V or less with the dual AC type (At an installation height of 300 mm) ・Rapid neutralization of static electricity by a feedback sensor ・Reduction of adjustment and maintenance labor by an auto balance sensor
DetailsEducational Animations
・Working principle
・3-Position Closed Center
・Working principle
・3-Position Exhaust Center
・Working principle
・3-Position Pressure Center
・Working principle
・Working principle
・Manual drain cock
・Working principle
・Float type auto drain(N.O.)
・Working principle
Details